% DEFINITION OF THE ELECTRICAL DOMAIN, WITH ASKABLES
% CILog code. Copyright David Poole, 1998.

% lit(L) is true if light L is lit.
lit(L) <-
   light(L) &
   ok(L) &
   live(L).

% live(W) is true if W is live (i.e., current will flow through it if grounded)
live(W) <-
   connectedto(W,W1) &
   live(W1).

live(outside).

% connectedto(W0,W1) is true if W0 is connnected to W1 such that current will
% flow from W1 to W0.

connectedto(l1,w0).
connectedto(w0,w1) <- up(s2) & ok(s2).
connectedto(w0,w2) <- down(s2) & ok(s2).
connectedto(w1,w3) <- up(s1) & ok(s1).
connectedto(w2,w3) <- down(s1) & ok(s1).
connectedto(l2,w4).
connectedto(w4,w3) <- up(s3) & ok(s3).
connectedto(p1,w3).
connectedto(w3,w5) <- ok(cb1).
connectedto(p2,w6).
connectedto(w6,w5) <- ok(cb2).
connectedto(w5,outside) <- ok(outside_connection).

% light(L) is true if L is a light
light(l1).
light(l2).

% up(S) is true if switch S is up
% down(S) is true if switch S is down

askable up(S).
askable down(S).

% ok(G) is true if G is working
% (assume for here that) everything is OK
ok(X).

% Example Queries:
% ask lit(L).